portable chillers

1st Choice Chillers | Products | Trouble Shooting | Manual | Load Sizing | Sitemap | Links | Clients | Components | Get a Quote

air chillers | mini | standard

 
air cooled chillers air cooled chillers air cooled chillers air cooled chillers

ACP 3 & 5
  (click image to enlarge)

ACP 7.5 & 10
 (click image to enlarge)

ACP 15D and 20D
 (click image to enlarge)

ACP 25D and 30D
 (click image to enlarge)

       

STANDARD CHILLERS (5 to 25 ton)

MODEL

AC-5

AC-7.5

AC-10

AC-10D

AC-15

AC-15D

AC-20D

ACP-25D* 

ACP-30D*

CAPACITY

CI

CI

CI

CI

CI

CI

CI

CI

CI

95 F PLANT AIR

CICI

CI

CI

CI

CI

CI

CI

CI

CI

LEAVING WATER

CICI

CI

CI

CI

CI

CI

CI

CI

CI

TEMP.

a

a

a

a

a

a

a

a

a

7.2C (45F)

4.1

6.1

8.7

8.7

12.6

12.6

16.0

21.5

25.2

10C (50F)

4.5

6.8

9.6

9.6

14.0

14.0

17.7

24.0

28.0

12C (55F)

5.0

7.5

10.5

10.5

15.4

15.4

19.5

26.0

30.0

REFRIGERATION

CI

CI

CI

CI

CI

CI

CI

CI

CI

CIRCUITS

1

1

1

2

2

2

2

 1

1

NUMBER OF

a

a

a

a

a

a

a

a

a

COMPRESSORS - HP

5  

7.5

10  

2 - 5 

1-15

2 - 7.5  

2 - 10

2 - 12.5

2-15

PUMP HP

1

1 1/2 

1 1/2 

2

5

5

CHILLER FLOW

a

a

a

a

a

a

a

a

a

gpm

12

18

24

24

36

36

48

60

72

m3/hr

2.7

4.1

5.4

5.4

8.1

8.1

10.9

13.5

16.2

CHILLER CONNECTIONS

CI

CI

CI

CI

CI

CI

CI

CI

inches

1 1/4

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

2

2

mm

31.7

38.1

38.1

38.1

38.1

38.1

50.8

50.8 

50.8

CONDENSER FANS - HP

1 - 1/2

1 - 1/2

1 - 1

1 - 1

2 - 3/4

2 - 3/4

2 - 1

2 - 1 1/2 

2 - 1 1/2 

CONDENSER CFM

4,500

5,670

7,790

7,790

11,340

11,340

16,120

22,000

22,000

SIZE L x W x H

a

a

a

a

a

a

a

a

a

inches

35x45x75

34x41x72

39x51x72

39x51x72

34x88x72

34x88x72

44x94x78

46x121x72 

46x121x72 

cm

89x117x190

87x104x183

99x130x183

99x130x183

87x234x183

87x234x183

118x239x198

116x307x183

 

116x307x183

WEIGHT

CI

CI

CI

CI

CI

CI

CI

CI

CI

lbs

CI

CI

CI

CI

CI

CI

CI

CI

CI

kg  

CI

CI

CI

CI

CI

CI

CI

CI

CI

KW AT DIFFERENT LEAVING

a

a

a

a

a

a

a

a

WATER TEMP. 45F

6.2

8.5

12.6

12.2

17.1

17.1

24.0

28.0

32.6

50F

6.5

8.9

13.2

12.7

18.6

18.6

25.0

30.0

35.0

55F

6.9

9.5

13.8

13.2

19.5

19.5

26.2

28.6

33.4

MIN. CIRCUIT AMPACITY

CI

CI

CI

CI

CI

CI

CI

CI

CI

208-220/1/60

41.0

CI

CI

CI

CI

CI

CI

CI

CI

208-230/3/60

29

40

58

51

64

68

97

100

120

460/3/60 

16

20

28

28

32

34

38

50

60

575/3/60

13

16

22

20

25

27

30

40

50

380-415/3/50

17

20

27

27

34

34

37

52

62

MAX. DUAL ELEMENT FUSE

a

a

a

a

a

a

a

a

208-220/1/60 

50

a

a

a

a

a

a

a

a

208-230/3/60 

40

60

80

60

80

80

125

110

130

460/3/60

20

30

40

35

45

45

50

60

70

575/3/60

20

30

35

25

35

35

40

50

60

380-414/3/50 

25

30

40

35

45

45

50

60

70


Capacity based on: Cooling 2.4 GPM of water from 60F to 50F (15.5C to 10C) at 95F (35C) ambient air temperature. Capacities, Dimensions and Weights are approximate and can change without notice

50 hertz operation: multiply capacity by 0.83 and kw by 0.85

-

*Please note that we can also supply the ACP-25 and ACP-30 with single compressors.

 
Copyright © 2008 | 1st Choice Portable Chillers | All rights reserved
 
1st Choice Portable Chillers, 111 Esna Park Drive, Unit 7, Markham, Ontario, L3R 1H2
Toll Free: 1,877. 513. 8310 ~ Email: sales@1stchoicechillers.com