Chiller Tank Sets
1st Choice Chillers manufactures chiller water
tank sets for the process cooling industry. We offer 7 standard models, each with double pumps, baffled tank and lid. The two
pump system has one pump dedicated to the chiller or chillers to maintain constant water flow required by the chillers to ensure
maximum efficiency and safe operation.
The second pump is dedicated to the process to supply higher flows than the chillers would normally allow, and higher water pressure required by the varing process equipment demand.
Click here for specifications on our Chiller Tank Sets
Benefits of the Chiller Water Pump Tank Set
Longer Lasting: Stainless steel tank, baffles and tank lid mounted on a rugged structural steel base that is
coated with a rust preventative paint.
Higher Operating Efficiency = Lower Operating Costs: Our pumps generally supply the same flow and pressure as
the competition with lower horsepower motors, normallly one size smaller.
Trouble Free Operation: With TEFC pump motors, liquid tight electrical conduit, industrial duty pumps and
motor starters.
Easy to Use: Our tank set design makes it easy to install, start up and operate.
Standard Features of the Chiller Water Tank Sets
Heavy guage stainless steel tank with 1/2" thick insulation mounted to a structural steel welded base coated with a rust
preventative paint.
Tank complete with: Process side thermometer and brass well, pump discharge pressure guages with brass shut-off valves, heavy-duy
bronze city water float make-up valve with bronze shut-off valve, 3" side overflow connection, and 1" side bottom drain connection with bronze shut-off valve.
Pump trim consists of the following:
- Suction: A bronze gate valve or lever-operated butterfly valve depending on whether the pump is threaded or has flanged connections. Galvanized union or steel flange for pump removal.
- Discharged: A galvanized union or flange for pump removal. Water-type check valve and a bronze ball valve or lever operated butterfly valve. Pump dischage pressure guages with brass shut-off valves.
- Industrial duty motor starters with thermal overloads and stop/start push buttons are mounted to the tank and prewired to the pump motors using liquid tight flexible conduit.
- Plant layout drawings showing customer's equipment location, cooling equipment location, pipe runs, line sizing and electrical requirements.
- Proper water distribution is critical to system operation and efficiency.
1st Choice Portable Chillers, 111 Esna Park Drive, Unit 7, Markham, Ontario, L3R 1H2
Toll Free: 1.877.513.8310 ~ Email: sales@1stchoicechillers.com